Repository logoGCRIS
  • English
  • Türkçe
  • Русский
Log In
New user? Click here to register. Have you forgotten your password?
Home
Communities
Browse GCRIS
Entities
Overview
GCRIS Guide
  1. Home
  2. Browse by Author

Browsing by Author "Usman, Ahmad Mustapha"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Master Thesis
    Hvdc iletim hattı güç dönüştürücü hata analizi
    (2019) Usman, Ahmad Mustapha; Kutay, Mahir
    Nüfus artışı, büyüyen kentler, artan enerji talebi ve artan çevre sorunları enerji iletim sistemlerinin yetersiz kalmasına yol açmaktadır. Özellikle yoğun nüfuslu bölgelerde yeni HVAC iletim hatlarının yapılması için yeterli alanı bulmak giderek zorlaşmaktadır. Yüksek güç iletim kapasitesine sahip ve daha az iletken kullanan HVDC iletim hatları bu tür kapasite arttırımlarımda HVAC ye göre daha ekonomiktir. Bu tezde, 500KV, 50HZ ve 330KV 60HZ iletim sistemlerini birbirine bağlayan, arka arkaya IGBT/DIODE tabanlı bir dönüştürücünün, sistemde oluşan herhangi bir anormallik sırasında verdiği cevabın MATHLAB/SIMULINK analizleri yapılmıştır. Ayrıca, HVDC'nin HVAC'ye dönüştürülmesi sırasında güç elektroniği elemanlarının kullanılması nedeniyle oluşan harmonik bileşenlerin %5 seviyesisini aşmaması için farklı süzgeç tipleri kullanılarak analizler yapılmıştır.
  • Loading...
    Thumbnail Image
    Conference Object
    Citation - WoS: 2
    Citation - Scopus: 5
    MATLAB/SIMULINK Model For HVDC Fault Calculations
    (IEEE, 2019) Ahmad Mustapha Usman; Mahir Kutay; Tuncay Ercan; Ercan, Tuncay; Usman, Ahmad Mustapha; Kutay, Mahir
    Power transmission has faced many challenges as the days goes by. Power demand has increased and its becoming increasingly difficult to acquire right way for new lines due to growth population urbanizations and environmental issues. This research aims to provide methods for the rationale selections of HVDC system essential HVDC equations and their control. A MATLAB/SIMULINK model is developed for a HVDC link using IGBT/DIODE converters between a 500KV 50Hz system to a 330KV 60Hz system over the distance of 450km. Analysis by using the model on this system identifies any abnormal behavior on the AC and DC sides and calculates the time elapsed for recovery to its reliable state conditions.
Repository logo
Collections
  • Scopus Collection
  • WoS Collection
  • TrDizin Collection
  • PubMed Collection
Entities
  • Research Outputs
  • Organizations
  • Researchers
  • Projects
  • Awards
  • Equipments
  • Events
About
  • Contact
  • GCRIS
  • Research Ecosystems
  • Feedback
  • OAI-PMH

Log in to GCRIS Dashboard

GCRIS Mobile

Download GCRIS Mobile on the App StoreGet GCRIS Mobile on Google Play

Powered by Research Ecosystems

  • Privacy policy
  • End User Agreement
  • Feedback