    Numerical analysis of a near-room-temperature magnetic cooling system, Analyse numérique d'un système de froid magnétique proche de la température ambiante
    (Elsevier Ltd, 2017) Mehmet Akif Ezan; Orhan Ekren; Cagri A.S. Metin; Ahmet Yilanci; Emrah Biyik; Salih Murat Kara; Ekren, Orhan; Yilanci, Ahmet; Kara, Salih Murat; Ezan, Mehmet Akif; Biyik, Emrah; Metin, Cagri
    In this study for a near-room-temperature magnetic cooling system a decoupled multi-physics numerical approach (Magnetism Fluid Flow and Heat Transfer) is developed using a commercial CFD solver ANSYS-FLUENT as a design tool. User defined functions are incorporated into the software in order to take into account the magnetocaloric effect. Magnetic flux density is assumed to be linear during the magnetization and demagnetization processes. Furthermore the minimum and maximum magnetic flux densities (Bmin and Bmax) are defined as 0.27 and 0.98 respectively. Two different sets of analyses are conducted by assuming an insulated cold heat exchanger (CHEX) and by defining an artificial cooling load in the CHEX. As a validation case experimental work from the literature is reproduced numerically and the results show that the current methodology is fairly accurate. Moreover parametric analyses are conducted to investigate the effect of the velocity of heat transfer fluid (HTF) and types of HTF on the performance of the magnetic cooling system. Also the performance metrics of the magnetic cooling system are investigated with regards to the temperature span of the magnetic cooling unit and the cooling load. It is concluded that reducing the cycle duration ensures reaching lower temperature values. Similarly reducing the velocity of the HTF allows reducing the outlet temperature of the HTF. In the current system the highest temperature spans are obtained numerically as around 6 K 5.2 K and 4.1 K for the cycle durations of 4.2 s 6.2 s and 8.2 s respectively. © 2017 Elsevier B.V. All rights reserved.
Repository logo
Collections
  • Scopus Collection
  • WoS Collection
  • TrDizin Collection
  • PubMed Collection
Entities
  • Research Outputs
  • Organizations
  • Researchers
  • Projects
  • Awards
  • Equipments
  • Events
About
  • Contact
  • GCRIS
  • Research Ecosystems
  • Feedback
  • OAI-PMH

Log in to GCRIS Dashboard

GCRIS Mobile

Download GCRIS Mobile on the App StoreGet GCRIS Mobile on Google Play

Powered by Research Ecosystems

  • Privacy policy
  • End User Agreement
  • Feedback