Abstract
This paper presents conventional and advanced exergoenvironmental analyses of an electricity generation facility located in the Eskisehir Industry Estate Zone Turkey. This facility consists of gas turbine and steam cycles which generate electrical power of approximately 37 MW and 18 MW respectively. Exergy efficiency of the system is 0.402 and exergy destruction rate of the system is 78.242 MW. Unit exergy cost of electrical power generated by the system is 25.66 $/GJ and total exergoeconomic factor of the system is 0.279. Conventional exergy analysis method was applied to the system first. Next exergy environmental impacts of exergy destruction rate within the facility's components were divided into four parts generally as endogenous exogenous avoidable and unavoidable environmental impact of exergy destruction rate. Through this analysis improvement potential of the environmental impacts of the components and the overall system and the environmental relations between the components were then determined. Finally exergoenvironmental factor was determined as 0.277 and environmental impact of the electricity was 8.472 (Pts/h). The system has 33% development potential for environmental impacts while its components have weak relations because of big endogenous parts of environmental impacts (80%). It may be concluded that advanced exergoenvironmental analysis indicated that priority should be given to the GT and CC while defining the improvement strategies. (C) 2014 Elsevier Ltd. All rights reserved.
Description
Keywords
Environmental assessment, Exergoenvironmental analysis, Advanced exergetic analysis, Advanced exergoenvironmental analysis, Exergy destruction rate, Electricity generation facility, ENVIRONMENTAL-IMPACT ASSESSMENT, CYCLE POWER-PLANT, COMBINED HEAT, EXERGY, ENERGY, SYSTEM, AID, Exergoenvironmental Analysis, Environmental Assessment, Advanced Exergetic Analysis, Electricity Generation Facility, Advanced Exergoenvironmental Analysis, Exergy Destruction Rate, Advanced Exergoenvironmental Analysis, Exergoenvironmental Analysis, Exergy Destruction Rate, Advanced Exergetic Analysis, Environmental Assessment, Electricity Generation Facility
Fields of Science
0211 other engineering and technologies, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
39
Source
Energy Conversion and Management
Volume
81
Issue
Start Page
112
End Page
119
PlumX Metrics
Citations
CrossRef : 11
Scopus : 40
Captures
Mendeley Readers : 60
Google Scholar™