Performance Assessment of University Buildings Based on Provided Thermal Comfort
| dc.contributor.author | Nurdan H. Yildirim | |
| dc.contributor.author | Hacer Sekerci Öztura | |
| dc.contributor.author | Sekerci, Hacer | |
| dc.contributor.author | Yildirim, Nurdan | |
| dc.date.accessioned | 2025-10-06T17:51:22Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Buildings and industry cover the largest share of total energy consumption. When the distribution of energy consumption in buildings is examined it is seen that the most important part is air conditioning systems. Therefore improving the energy consumption of air conditioning systems or using more efficient systems have great importance. The factors affecting the energy consumption of air conditioning systems are system type capacity design operation and climate conditions and user interventions.Yasar University is the first University having the TS EN ISO 50001:2011 Energy Management System Standard Certification in Turkey. Since the buildings and their systems are different in the Campus the new performance indicators are necessary to evaluate energy performance of the buildings. In this regard addition to existing energy metering system thermal comfort measurement devices were installed in some classes and offices in the campus.In this study performance assessment of two buildings in the Campus of Yasar University has been done based on their specific energy consumption and provided thermal comfort to the classes. Thus the relationship between energy consumption and thermal comfort in buildings is revealed and suggestions are presented to increase energy efficiency. © 2020 Elsevier B.V. All rights reserved. | |
| dc.description.sponsorship | Project Evaluation Commission; Yaşar University; Yaşar University Project Evaluation Commission | |
| dc.description.sponsorship | ACKNOWLEDGMENT This study was supported by the Project Evaluation Commission (PDK) of Yaşar University. We would like to thank to Yaşar University Project Evaluation Commission for supporting the project by providing financial means for the realization of this study. | |
| dc.identifier.doi | 10.1109/ACEEE.2019.8817007 | |
| dc.identifier.isbn | 9781728136547 | |
| dc.identifier.scopus | 2-s2.0-85072760413 | |
| dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072760413&doi=10.1109%2FACEEE.2019.8817007&partnerID=40&md5=e412cc261e950eba8077034765ee9d7c | |
| dc.identifier.uri | https://gcris.yasar.edu.tr/handle/123456789/9401 | |
| dc.identifier.uri | https://doi.org/10.1109/ACEEE.2019.8817007 | |
| dc.language.iso | English | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.relation.ispartof | 2nd Asia Conference on Energy and Environment Engineering ACEEE 2019 | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Buildings, Energy Consumption, Energy Efficiency, Hvac-r Systems, Thermal Comfort, Air Conditioning, Buildings, College Buildings, Energy Management Systems, Energy Utilization, Thermal Comfort, Distribution Of Energy Consumption, Energy Performance, Existing Energies, Measurement Device, Performance Assessment, Performance Indicators, Specific Energy Consumption, Total Energy Consumption, Energy Efficiency | |
| dc.subject | Air conditioning, Buildings, College buildings, Energy management systems, Energy utilization, Thermal comfort, Distribution of energy consumption, Energy performance, Existing energies, Measurement device, Performance assessment, Performance indicators, Specific energy consumption, Total energy consumption, Energy efficiency | |
| dc.subject | HVAC-R Systems | |
| dc.subject | Energy Consumption | |
| dc.subject | Thermal Comfort | |
| dc.subject | Buildings | |
| dc.subject | Energy Efficiency | |
| dc.title | Performance Assessment of University Buildings Based on Provided Thermal Comfort | |
| dc.type | Conference Object | |
| dspace.entity.type | Publication | |
| gdc.author.scopusid | 14061388000 | |
| gdc.author.scopusid | 6506751324 | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C5 | |
| gdc.coar.type | text::conference output | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | ||
| gdc.description.departmenttemp | [Yildirim N.] Department of Energy Systems Engineering, Yasar University, Izmir, Turkey; [Sekerci H.] Department of Electric-Electronic Engineering, Yasar University, Izmir, Turkey | |
| gdc.description.endpage | 11 | |
| gdc.description.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | |
| gdc.description.startpage | 7 | |
| gdc.identifier.openalex | W2970176613 | |
| gdc.index.type | Scopus | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 2.0 | |
| gdc.oaire.influence | 2.533467E-9 | |
| gdc.oaire.isgreen | true | |
| gdc.oaire.popularity | 2.6977702E-9 | |
| gdc.oaire.publicfunded | false | |
| gdc.oaire.sciencefields | 0202 electrical engineering, electronic engineering, information engineering | |
| gdc.oaire.sciencefields | 02 engineering and technology | |
| gdc.openalex.collaboration | National | |
| gdc.openalex.fwci | 0.4755 | |
| gdc.openalex.normalizedpercentile | 0.68 | |
| gdc.opencitations.count | 3 | |
| gdc.plumx.crossrefcites | 2 | |
| gdc.plumx.mendeley | 20 | |
| gdc.plumx.scopuscites | 5 | |
| gdc.scopus.citedcount | 5 | |
| gdc.virtual.author | Yildirim Özcan, Nurdan | |
| gdc.virtual.author | Öztura, Hacer | |
| oaire.citation.endPage | 11 | |
| oaire.citation.startPage | 7 | |
| person.identifier.scopus-author-id | Yildirim- Nurdan H. (14061388000), Öztura- Hacer Sekerci (6506751324) | |
| project.funder.name | ACKNOWLEDGMENT This study was supported by the Project Evaluation Commission (PDK) of Yaşar University. We would like to thank to Yaşar University Project Evaluation Commission for supporting the project by providing financial means for the realization of this study. | |
| relation.isAuthorOfPublication | bd8ae595-18d5-4c65-9320-fc740b9b6154 | |
| relation.isAuthorOfPublication | 4b524a56-5270-4b9f-810c-185bf6d0a0a6 | |
| relation.isAuthorOfPublication.latestForDiscovery | bd8ae595-18d5-4c65-9320-fc740b9b6154 | |
| relation.isOrgUnitOfPublication | ac5ddece-c76d-476d-ab30-e4d3029dee37 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ac5ddece-c76d-476d-ab30-e4d3029dee37 |