The performance comparison of fan-assisted Trombe wall system

dc.contributor.author Basak Kundakci Koyunbaba
dc.contributor.author Zerrin Yilmaz
dc.contributor.author Kundakçi Koyunbaba, Başak
dc.contributor.author Yilmaz, Zerrin
dc.date.accessioned 2025-10-06T17:52:48Z
dc.date.issued 2013
dc.description.abstract One of the various systems used for energy conservation in buildings is building integrated photovoltaic (BIPV) Trombe wall system. This system is applied to the blind south facades of buildings to produce heat and electrical energy. In this paper the energy performance comparison of fan-assisted single glass double glass and a-Si semi-transparent PV module integrated on the Trombe wall façade of a model test room built in Izmir Turkey has been carried out. The system has been operated during 19 - 21 January. The temperature variations at certain nodes where the temperature probes are placed have been evaluated. The measured values of inter-space inlet and outlet air temperatures for single glass double glass and photovoltaic module have been compared. The surface temperatures of the photovoltaic module and the thermal wall have also been evaluated. The comparison of the thermal performance for three modules has been made according to the experimental results. The change in electrical efficiency by surface temperature of the photovoltaic module has also been interpreted. According to the experimental results 10% of solar radiation has been transmitted through the semi-transparent photovoltaic module. Meanwhile the electrical efficiency of PV cells can reach 4.5 % according to the experimental results. © 2023 Elsevier B.V. All rights reserved.
dc.identifier.issn 25647571, 25647474
dc.identifier.issn 2564-7474
dc.identifier.scopus 2-s2.0-84894613084
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-84894613084&partnerID=40&md5=900438a083407e4c0e642030856a2a56
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/10131
dc.language.iso English
dc.publisher Istanbul Teknik Universitesi Faculty of Architecture
dc.relation.ispartof A/Z ITU Journal of the Faculty of Architecture
dc.rights info:eu-repo/semantics/closedAccess
dc.source A/Z ITU Journal of the Faculty of Architecture
dc.subject Bipv Trombe Wall System, Electric Output, Electrical Efficiency, Forced Convection, Thermal Storage
dc.subject Thermal Storage
dc.subject Electrical Efficiency
dc.subject BIPV Trombe Wall System
dc.subject Electric Output
dc.subject Forced Convection
dc.title The performance comparison of fan-assisted Trombe wall system
dc.type Article
dspace.entity.type Publication
gdc.author.scopusid 42861760700
gdc.author.scopusid 56261716400
gdc.coar.type text::journal::journal article
gdc.description.department
gdc.description.departmenttemp [Kundakçi Koyunbaba B.] Yasar University, Izmir, Turkey; [Yilmaz Z.] Istanbul Technical University, Istanbul, Turkey
gdc.description.endpage 211
gdc.description.issue 2
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
gdc.description.startpage 198
gdc.description.volume 10
gdc.index.type Scopus
gdc.scopus.citedcount 8
gdc.virtual.author Kundakçi Koyunbaba, Başak
oaire.citation.endPage 211
oaire.citation.startPage 198
person.identifier.scopus-author-id Koyunbaba- Basak Kundakci (42861760700), Yilmaz- Zerrin (56261716400)
publicationissue.issueNumber 2
publicationvolume.volumeNumber 10
relation.isAuthorOfPublication 32fbbf6b-564a-4406-9a61-6715403cafa3
relation.isAuthorOfPublication.latestForDiscovery 32fbbf6b-564a-4406-9a61-6715403cafa3
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files