First and second law analyses of wastewater cooled condenser for a refrigeration system
Loading...

Date
2019
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Inderscience Publishers
Open Access Color
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
In this study a vapour compression refrigeration (VCR) system with a wastewater (WW) cooled condenser at a temperature range of 27-29°C was designed. The cooling capacity of the system using R134a as the refrigerant was 1.09 kW. The condenser consisted of a coaxial heat exchanger with a capacity of 1 kW. This paper dealt with energy and exergy analyses of the VCR system using WW as a heat sink. Experiments were performed in order to evaluate the energetic and exergetic performances of the wastewater-cooled condenser (WWC) and the overall system. The convective heat transfer coefficient of WW and refrigerant in the condenser overall heat transfer coefficient of the WWC total amount of heat removed by WW amount of cooling effect coefficient of performance (COP) exergy destruction rate and second law efficiencies of the WWC and VCR system were calculated under different WW temperatures and flowrates. Increasing volumetric flowrate of WW from 200 L/h to 400 L/h caused 4.4% improvement in COP 12.0% reduction in exergy destruction and 10.3% increase in exergy efficiency. © 2020 Elsevier B.V. All rights reserved.
Description
Keywords
Coefficient Of Performance, Cop, Energy, Exergy, Refrigeration, Second Law Efficiency, Wastewater, Binary Alloys, Coefficient Of Performance, Exergy, Heat Convection, Heat Exchangers, Heat Transfer Coefficients, Refrigerants, Refrigeration, Wastewater, Coaxial Heat Exchangers, Coefficient Of Performances (cop), Convective Heat Transfer Coefficient, Energy, Energy And Exergy Analysis, Overall Heat Transfer Coefficient, Second Law Efficiencies, Vapour Compression Refrigerations, Heat Transfer Performance, Binary alloys, Coefficient of performance, Exergy, Heat convection, Heat exchangers, Heat transfer coefficients, Refrigerants, Refrigeration, Wastewater, Coaxial heat exchangers, Coefficient of performances (COP), Convective heat transfer Coefficient, Energy, Energy and exergy analysis, Overall heat transfer coefficient, Second law efficiencies, Vapour compression refrigerations, Heat transfer performance, Coefficient of Performance, Wastewater, Refrigeration, COP, Exergy, Second Law Efficiency, Energy, exergy, second law efficiency, refrigeration, wastewater, coefficient of performance, energy, COP
Fields of Science
0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
1
Source
International Journal of Exergy
Volume
29
Issue
2-4
Start Page
155
End Page
171
Collections
PlumX Metrics
Citations
Scopus : 2
Captures
Mendeley Readers : 5
Google Scholar™


