Abstract
In this study performance of viscous dampers as an alternative retrofitting technique in a building is evaluated. Büyük Halkalı Primary School Building in İstanbul is considered as a case study. The building was constructed in 1997 and retrofitted in 2006 using conventional methods. In 2019 the building was reassessed according to the Turkish Building Seismic Code (TBDY-2018) and strengthening was achieved by additional shear walls. In this study different from the previous approach directivity effects of the ground motion were also considered in addition to the code specific design spectrum. Nonlinear time-history analyses were performed according to TBDY-2018. The retrofit design aimed to enhance the building's seismic performance and reduce potential damage during a seismic event. The design included the installation of seismic dampers which are devices that dissipate seismic energy and reduce the building's response to ground motion. The seismic dampers were strategically placed to control the building's response to seismic forces and limit the structural damage. Both retrofit options (conventional method and the viscous dampers alternative) were compared in terms of cost serviceability architectural benefits and construction time. © 2024 Elsevier B.V. All rights reserved.
Description
Keywords
Retrofitting, Time-history Analysis, Viscous Dampers, Architectural Design, Damping, Seismic Design, Seismic Response, Structural Dynamics, Case-studies, Conventional Methods, Ground-motion, Performance, Primary Schools, Seismic Dampers, Seismic Retrofitting, Time History Analysis, Turkishs, Viscous Dampers, Retrofitting, Architectural design, Damping, Seismic design, Seismic response, Structural dynamics, Case-studies, Conventional methods, Ground-motion, Performance, Primary schools, Seismic dampers, Seismic retrofitting, Time history analysis, Turkishs, Viscous dampers, Retrofitting, Viscous Dampers, Time-History Analysis, Retrofitting
Fields of Science
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
1
Source
18th World Conference on Seismic Isolation Energy Dissipation and Active Vibration Control of Structures WCSI 2023
Volume
412
Issue
Start Page
253
End Page
266
PlumX Metrics
Citations
Scopus : 0
Captures
Mendeley Readers : 2
Google Scholar™