Extended exergy analysis of a novel integrated absorptional cooling system design without utilization of generator for economical and robust provision of higher cooling demands

Loading...
Publication Logo

Date

2024

Authors

Asli Tiktas
Huseyin Gunerhan
Arif Hepbasli
Emin Acikkalp

Journal Title

Journal ISSN

Volume Title

Publisher

PERGAMON-ELSEVIER SCIENCE LTD

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

The focus of this study is on designing a novel system for the provision of high-capacity cooling and heating loads (4000 kW) with the utilization of absorption technology to increase economic viability and COP value of existing cooling plants via lower-grade waste heat sources (70 degrees C-90 degrees C). To achieve this aim in the novel system an integration including the LiBr-water solution based absorptional heat transformer (AHT) and absorptional cooling cycle (ACC) and flat plate solar collector (FPSC) systems was proposed. In the integration the utilization of the generator in the cooling cycle was avoided with the interaction of the high-temperature LiBr-water solution (120 degrees C-150 degrees C) from the AHT system and ACC system evaporator. In this way both the additional cost of the boiler and heat source and the enhancement of economic viability and COP value were achieved. Energy economic traditional and extended exergy sustainability and environmental analyses were implemented in this novel system. The COP value for the cooling system was determined to be 3.10 from energy analysis. This result forms a significant indicator for achieving of the main focus of the current study with the proposed novel system. The annual heating and cooling duty generations with this novel system were computed as 52.37 GWh and 52.40 GWh respectively. In the context of economically comparing the proposed system to other plants with similar scale that already exist the initial overall expenditure yearly operational expenses and the time it takes to recover the investment for the proposed system were set at $4.56 million $3.12 million and 1.75 years respectively. It is worth noting though that these figures fall within the range of $6 - 8 million $5 - 7 million and 5 - 10 years respectively for the currently operational plants. This result indicated that the proposed system provides a robust alternative to the existing cooling-heating cogeneration systems in terms of main output generation and is more economically viable. Also the novel system gained annually US$3.89 million in energy costs. The conventional exergy analysis results were summarized by forming an exergy flow and loss diagram namely the Grassmann diagram. In addition in this current study the novel extended exergy flow diagram indicating extended exergy content components energy carriers of the proposed system and exergy product rate streams was also proposed and drawn for the proposed system.

Description

Keywords

Absorptional cooling cycle, Solar energy, Absorptional heat transformer, Extended exergy analysis, Environmental impact assessment, POWER, PLANT, WATER, CYCLE, Environmental Impact Assessment, Extended Exergy Analysis, Solar Energy, Absorptional Heat Transformer, Absorptional Cooling Cycle, Absorptional cooling cycle, Solar energy, Extended exergy analysis, Environmental impact assessment, Absorptional heat transformer

Fields of Science

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
6

Source

Energy Conversion and Management

Volume

307

Issue

Start Page

118350

End Page

PlumX Metrics
Citations

Scopus : 10

Captures

Mendeley Readers : 13

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
3.4069

Sustainable Development Goals

AFFORDABLE AND CLEAN ENERGY7
AFFORDABLE AND CLEAN ENERGY