IMPROVING THE PERFORMANCE OF A HEATING SYSTEM THROUGH ENERGY MANAGEMENT BY USING EXERGY PARAMETERS

dc.contributor.author Cem Tahsin Yucer
dc.contributor.author Arif Hepbasli
dc.date.accessioned 2025-10-06T16:20:34Z
dc.date.issued 2020
dc.description.abstract Energy management systems are used to analyze the efficiency of energy systems and identify any problem areas to lower costs and save energy typically using energy based performance measurements. Our aim was to use exergy parameters instead to see if more accurate information could be obtained about which energy saving application would result in greater energy savings. Exergy analysis is based on the Second law of thermodynamics and focuses on the environment and the quality of the energy. Implementing an exergetic approach to analyze a steam heating system we examined data related to exergy flows and exergy losses and ultimately improved the performance of the system through this energy management model. The following seven energy saving applications were identified and ranked according to their improvement potentials: adjusting the air to fuel ratio - 1 preventing steam leaks - 2 installing an automatic blow down system - 3 insulating the pipes - 4 insulating valves and flanges -5 insulating fuel tank -6 and recovering heat loss from the waste condensate -7. The optimum ranking obtained through the exergy analysis was 3-1-2-5-7-6-4. A reduction of 15.918 kW in exergy consumption was achieved by installing an automatic blowdown system. This meant a total reduction of 1779.03 kg per year in total fuel consumption $1458.81 per year of cost reduction and the total cost reduction achieved was $1829.25 per year. Making improvements to the seven selected areas in the system 38.4% of the energy loss was recovered while the recovery in the exergy consumption was 44.5%.Y
dc.identifier.doi 10.2298/TSCI181101107Y
dc.identifier.issn 0354-9836
dc.identifier.issn 2334-7163
dc.identifier.uri http://dx.doi.org/10.2298/TSCI181101107Y
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/6442
dc.language.iso English
dc.publisher VINCA INST NUCLEAR SCI
dc.relation.ispartof Thermal Science
dc.source THERMAL SCIENCE
dc.subject energy management, exergy analysis, exergy metrics, cost reduction
dc.subject POWER, IMPROVEMENT
dc.title IMPROVING THE PERFORMANCE OF A HEATING SYSTEM THROUGH ENERGY MANAGEMENT BY USING EXERGY PARAMETERS
dc.type Article
dspace.entity.type Publication
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.endpage 3780
gdc.description.startpage 3771
gdc.description.volume 24
gdc.identifier.openalex W2931755728
gdc.index.type WoS
gdc.oaire.accesstype GOLD
gdc.oaire.diamondjournal false
gdc.oaire.impulse 1.0
gdc.oaire.influence 2.451169E-9
gdc.oaire.isgreen false
gdc.oaire.popularity 1.9982185E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.collaboration National
gdc.openalex.fwci 0.0579
gdc.openalex.normalizedpercentile 0.37
gdc.opencitations.count 1
gdc.plumx.crossrefcites 1
gdc.plumx.mendeley 6
gdc.plumx.scopuscites 2
oaire.citation.endPage 3780
oaire.citation.startPage 3771
person.identifier.orcid Yucer- Cem Tahsin/0000-0002-4848-867X,
publicationissue.issueNumber 6
publicationvolume.volumeNumber 24
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files