Quality Assurance for Operating Room Illumination through Lean Six Sigma

dc.contributor.author Yucel Yilmaz Ozturkoglu
dc.contributor.author Yigit Kazancoglu
dc.contributor.author Muhittin Saǧnak
dc.contributor.author Jose Arturo Garza-Reyes
dc.date.accessioned 2025-10-06T17:50:31Z
dc.date.issued 2021
dc.description.abstract Since every mistake made in the healthcare industry can cause permanent harm or even death some fundamental requirements should be considered when planning and designing operating rooms. Lighting is one of the most important ergonomic factors especially for operating rooms. This paper investigates the integration of the lean approach and six sigma in measuring the efficiency of LED technology which can also be regarded as a factor affecting the operating room efficiency. Measurement System Analysis (MSA) and Gage Control methods were applied to determine measurement variability in operating room illumination measurement process. Repeatability and reproducibility (%R&R) was found 12.89%. After calibration %R&R value was found 8.21% which implies that calibration helped reduce variability. © 2023 Elsevier B.V. All rights reserved.
dc.identifier.doi 10.33889/ijmems.2021.6.3.045
dc.identifier.issn 24557749
dc.identifier.issn 2455-7749
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-85107683729&doi=10.33889%2Fijmems.2021.6.3.045&partnerID=40&md5=5c48507b1379df2a8cb0e7e6e908073d
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/8964
dc.language.iso English
dc.publisher International Journal of Mathematical Engineering and Management Sciences
dc.relation.ispartof International Journal of Mathematical, Engineering and Management Sciences
dc.source International Journal of Mathematical Engineering and Management Sciences
dc.subject -operating Rooms, Gage Control, Lean Approach, Lighting, Measurement System Analysis, Six Sigma, Calibration, Efficiency, Lighting, Operating Rooms, Process Monitoring, Quality Assurance, Quality Control, Systems Analysis, Work Simplification, -operating Room, Control Methods, Gage Control, Healthcare Industry, Lean Approach, Lean Six Sigma, Measurement Process, Measurement Systems Analysis, Planning And Designings, Six-sigma, Six Sigma
dc.subject Calibration, Efficiency, Lighting, Operating rooms, Process monitoring, Quality assurance, Quality control, Systems analysis, Work simplification, -operating room, Control methods, Gage control, Healthcare industry, Lean approach, Lean Six Sigma, Measurement process, Measurement systems analysis, Planning and designings, Six-Sigma, Six sigma
dc.title Quality Assurance for Operating Room Illumination through Lean Six Sigma
dc.type Article
dspace.entity.type Publication
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.endpage 770
gdc.description.startpage 752
gdc.description.volume 6
gdc.identifier.openalex W3164890002
gdc.index.type Scopus
gdc.oaire.accesstype GOLD
gdc.oaire.diamondjournal false
gdc.oaire.impulse 2.0
gdc.oaire.influence 2.5060927E-9
gdc.oaire.isgreen false
gdc.oaire.keywords Technology
gdc.oaire.keywords gage control
gdc.oaire.keywords Operating rooms
gdc.oaire.keywords lighting
gdc.oaire.keywords T
gdc.oaire.keywords six sigma
gdc.oaire.keywords operating rooms
gdc.oaire.keywords measurement system analysis
gdc.oaire.keywords QA1-939
gdc.oaire.keywords lean approach
gdc.oaire.keywords Mathematics
gdc.oaire.popularity 4.374656E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 03 medical and health sciences
gdc.oaire.sciencefields 0302 clinical medicine
gdc.oaire.sciencefields 0305 other medical science
gdc.openalex.collaboration International
gdc.openalex.fwci 1.3826
gdc.openalex.normalizedpercentile 0.81
gdc.opencitations.count 3
gdc.plumx.mendeley 67
gdc.plumx.scopuscites 6
oaire.citation.endPage 770
oaire.citation.startPage 752
person.identifier.scopus-author-id Ozturkoglu- Yucel Yilmaz (37065136900), Kazancoglu- Yigit (15848066400), Saǧnak- Muhittin (55505122500), Garza-Reyes- Jose Arturo (35310169200)
publicationissue.issueNumber 3
publicationvolume.volumeNumber 6
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files