Avoidable thermodynamic inefficiencies evaluation of a sewage water source heat pump system
Loading...

Date
2023
Authors
Aysegul Gungor Celik
A. Hepbasli
Journal Title
Journal ISSN
Volume Title
Publisher
Inderscience Publishers
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
The performance of a sewage water source heat pump system is assessed through conventional/enhanced exergy-based methods in this present study. The experimental data used in the analyses are based the cooling mode. According to the conventional-based results the condenser has the lowest exergy efficiency. Beside this the enhanced exergy-based analysis results show the sewage water heat exchanger should be considered as the most significant component as it has the highest avoidable exergy destruction rate in the whole system and takes the improvement priority. Based on the enhanced exergy analysis 56% of the total exergy destruction belongs to the avoidable part. © 2023 Elsevier B.V. All rights reserved.
Description
Keywords
Advanced Exergy Analysis, Conventional Exergy Analysis, Enhanced Exergy Analysis, Sewage Water Source Heat Pump, Swshp, Waste Heat, Heat Pump Systems, Pumps, Sewage, Waste Heat, Advanced Exergy Analyse, Conventional Exergy Analyse, Enhanced Exergy Analyse, Exergy Analysis, Sewage Water, Sewage Water Source Heat Pump, Swshp, Water Source Heat Pump, Exergy, Heat pump systems, Pumps, Sewage, Waste heat, Advanced exergy analyse, Conventional exergy analyse, Enhanced exergy analyse, Exergy Analysis, Sewage water, Sewage water source heat pump, SWSHP, Water source heat pump, Exergy
Fields of Science
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
N/A
Source
International Journal of Exergy
Volume
40
Issue
Start Page
414
End Page
Collections
PlumX Metrics
Citations
Scopus : 1
Google Scholar™