A comparative study on conventional and advanced exergetic analyses of geothermal district heating systems based on actual operational data

dc.contributor.author A. Hepbasli
dc.contributor.author Ali Keçebaş
dc.contributor.author Hepbasli, Arif
dc.contributor.author Kecebas, Ali
dc.date.accessioned 2025-10-06T17:52:47Z
dc.date.issued 2013
dc.description.abstract This paper comparatively evaluates exergy destructions of a geothermal district heating system (GDHS) using both conventional and advanced exergetic analysis methods to identify the potential for improvement and the interactions among the components. As a real case study the Afyon GDHS in Afyonkarahisar Turkey is considered based on actual operational data. For the first time advanced exergetic analysis is applied to the GDHSs in which the exergy destruction rate within each component is split into unavoidable/avoidable and endogenous/exogenous parts. The results indicate that the interconnections among all the components are not very strong. Thus one should focus on how to reduce the internal inefficiency (destruction) rates of the components. The highest priority for improvement in the advanced exergetic analysis is in the re-injection pump (PM-IX) while it is the heat exchanger (HEX-III) in the conventional analysis. In addition there is a substantial influence on the overall system as the total avoidable exergy destruction rate of the heat exchanger (HEX-V) has the highest value. On the overall system basis the value for the conventional exergetic efficiency is determined to be 29.29% while that for the modified exergetic efficiency is calculated to be 34.46% through improving the overall components. © 2013 Elsevier B.V. © 2013 Elsevier B.V. All rights reserved.
dc.description.sponsorship The authors would like to thank for the support provided by the Afyon Geothermal Inc., Turkey.
dc.description.sponsorship Afyon Geothermal Inc., Turkey
dc.identifier.doi 10.1016/j.enbuild.2013.02.019
dc.identifier.issn 03787788
dc.identifier.issn 0378-7788
dc.identifier.scopus 2-s2.0-84875184606
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-84875184606&doi=10.1016%2Fj.enbuild.2013.02.019&partnerID=40&md5=c04020eef56c8f7f798cf0c44a412e43
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/10112
dc.identifier.uri https://doi.org/10.1016/j.enbuild.2013.02.019
dc.language.iso English
dc.publisher Elsevier Science SA
dc.relation.ispartof Energy and Buildings
dc.rights info:eu-repo/semantics/closedAccess
dc.source Energy and Buildings
dc.subject Advanced Exergetic Analysis, Buildings, Conventional Exergetic Analysis, District Heating System, Exergy Destruction, Geothermal Energy, Advanced Exergetic Analysis, Avoidable Exergy Destructions, Comparative Studies, Conventional Exergetic Analysis, District Heating System, Exergetic Efficiency, Exergy Destructions, Geothermal District Heating System, Buildings, District Heating, Geothermal Energy, Geothermal Heating, Heat Exchangers, Exergy
dc.subject Advanced exergetic analysis, Avoidable exergy destructions, Comparative studies, Conventional exergetic analysis, District heating system, Exergetic efficiency, Exergy destructions, Geothermal district heating system, Buildings, District heating, Geothermal energy, Geothermal heating, Heat exchangers, Exergy
dc.subject Geothermal Energy
dc.subject Conventional Exergetic Analysis
dc.subject Advanced Exergetic Analysis
dc.subject Buildings
dc.subject District Heating System
dc.subject Exergy Destruction
dc.title A comparative study on conventional and advanced exergetic analyses of geothermal district heating systems based on actual operational data
dc.type Article
dspace.entity.type Publication
gdc.author.scopusid 55131010100
gdc.author.scopusid 14068776900
gdc.author.wosid Hepbasli, Arif/I-5733-2012
gdc.author.wosid Keçebaş, Ali/JJD-7757-2023
gdc.bip.impulseclass C4
gdc.bip.influenceclass C4
gdc.bip.popularityclass C4
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department
gdc.description.departmenttemp [Hepbasli, Arif] Yasar Univ, Fac Engn, Dept Energy Syst Engn, TR-35100 Izmir, Turkey; [Kecebas, Ali] Mugla Sitki Kocman Univ, Fac Technol, Dept Energy Syst Engn, Mugla, Turkey
gdc.description.endpage 201
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
gdc.description.startpage 193
gdc.description.volume 61
gdc.description.woscitationindex Science Citation Index Expanded
gdc.identifier.openalex W2020320562
gdc.identifier.wos WOS:000320485500024
gdc.index.type Scopus
gdc.index.type WoS
gdc.oaire.diamondjournal false
gdc.oaire.impulse 16.0
gdc.oaire.influence 5.0230002E-9
gdc.oaire.isgreen true
gdc.oaire.popularity 1.1722601E-8
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0211 other engineering and technologies
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.collaboration National
gdc.openalex.fwci 8.2597
gdc.openalex.normalizedpercentile 0.98
gdc.openalex.toppercent TOP 10%
gdc.opencitations.count 34
gdc.plumx.crossrefcites 21
gdc.plumx.mendeley 46
gdc.plumx.scopuscites 40
gdc.scopus.citedcount 40
gdc.virtual.author Hepbaşli, Arif
gdc.wos.citedcount 38
oaire.citation.endPage 201
oaire.citation.startPage 193
person.identifier.scopus-author-id Hepbasli- A. (55131010100), Keçebaş- Ali (14068776900)
project.funder.name The authors would like to thank for the support provided by the Afyon Geothermal Inc. Turkey.
publicationvolume.volumeNumber 61
relation.isAuthorOfPublication 5ed55b5a-c6f7-47f9-9ff2-354ea25b338e
relation.isAuthorOfPublication.latestForDiscovery 5ed55b5a-c6f7-47f9-9ff2-354ea25b338e
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files