Experimental exergoeconomic assessment of a desiccant cooling system

Loading...
Publication Logo

Date

2013

Authors

Ertaç Hürdoǧan
Orhan Büyükalaca
M. Tolga Balta
A. Hepbasli
Tuncay Yilmaz

Journal Title

Journal ISSN

Volume Title

Publisher

Pergamon-Elsevier Science Ltd

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

0

OpenAIRE Views

3

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Average

Research Projects

Journal Issue

Abstract

Desiccant cooling has become a well established technology in most parts of the world especially recently in Turkey. The increased growth of the technology was caused by the contribution of refrigerants used in conventional cooling systems to the depletion of the ozone layer. This technology provides a tool to control humidity (moisture) levels in conditioned air spaces. In this study a desiccant cooling system was designed constructed and tested in Cukurova University Adana Turkey while it has been successfully operated since 2008. Exergy cost energy and mass (EXCEM) analysis was applied to this system for the first time to the best of the authors' knowledge. The relations between thermodynamic losses and capital costs were also parametrically investigated and illustrated in figures. Based on the overall system (OS) results some components of the whole system namely the electric heater unit the expansion valve the pump the fresh air fan and the condenser fan were obtained to be inefficient. Particularly the electric heater unit was important as its exergy loss rate (Ṙ<inf>ex</inf>) value was 29.36 times greater than that of the OS. © 2013 Elsevier Ltd. All rights reserved. © 2013 Elsevier B.V. All rights reserved.

Description

Keywords

Desiccant Cooling, Excem, Exergoeconomic, Exergy Analysis, Air Space, Capital Costs, Desiccant Cooling, Desiccant Cooling Systems, Electric Heater, Excem, Exergoeconomic, Exergy Analysis, Exergy Loss, Expansion Valves, Fresh Air, Thermodynamic Loss, Cooling Systems, Driers (materials), Electric Heat Treatment, Electric Heating, Exergy, Heating Equipment, Humidity Control, Ozone Layer, Cost Benefit Analysis, Air space, Capital costs, Desiccant cooling, Desiccant cooling systems, Electric heater, EXCEM, Exergoeconomic, Exergy Analysis, Exergy loss, Expansion valves, Fresh air, Thermodynamic loss, Cooling systems, Driers (materials), Electric heat treatment, Electric heating, Exergy, Heating equipment, Humidity control, Ozone layer, Cost benefit analysis, Exergoeconomic, Desiccant Cooling, EXCEM, Exergy Analysis, Exergoeconomic, Desiccant Cooling, Exergy Analysis, EXCEM

Fields of Science

0211 other engineering and technologies, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
12

Source

Energy Conversion and Management

Volume

69

Issue

Start Page

9

End Page

16
PlumX Metrics
Citations

CrossRef : 10

Scopus : 12

Captures

Mendeley Readers : 55

SCOPUS™ Citations

12

checked on Apr 09, 2026

Web of Science™ Citations

12

checked on Apr 09, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
3.7168

Sustainable Development Goals

SDG data is not available