Experimental exergoeconomic assessment of a desiccant cooling system
Loading...

Date
2013
Authors
Ertaç Hürdoǧan
Orhan Büyükalaca
M. Tolga Balta
A. Hepbasli
Tuncay Yilmaz
Journal Title
Journal ISSN
Volume Title
Publisher
Pergamon-Elsevier Science Ltd
Open Access Color
Green Open Access
Yes
OpenAIRE Downloads
0
OpenAIRE Views
3
Publicly Funded
No
Abstract
Desiccant cooling has become a well established technology in most parts of the world especially recently in Turkey. The increased growth of the technology was caused by the contribution of refrigerants used in conventional cooling systems to the depletion of the ozone layer. This technology provides a tool to control humidity (moisture) levels in conditioned air spaces. In this study a desiccant cooling system was designed constructed and tested in Cukurova University Adana Turkey while it has been successfully operated since 2008. Exergy cost energy and mass (EXCEM) analysis was applied to this system for the first time to the best of the authors' knowledge. The relations between thermodynamic losses and capital costs were also parametrically investigated and illustrated in figures. Based on the overall system (OS) results some components of the whole system namely the electric heater unit the expansion valve the pump the fresh air fan and the condenser fan were obtained to be inefficient. Particularly the electric heater unit was important as its exergy loss rate (Ṙ<inf>ex</inf>) value was 29.36 times greater than that of the OS. © 2013 Elsevier Ltd. All rights reserved. © 2013 Elsevier B.V. All rights reserved.
Description
ORCID
Keywords
Desiccant Cooling, Excem, Exergoeconomic, Exergy Analysis, Air Space, Capital Costs, Desiccant Cooling, Desiccant Cooling Systems, Electric Heater, Excem, Exergoeconomic, Exergy Analysis, Exergy Loss, Expansion Valves, Fresh Air, Thermodynamic Loss, Cooling Systems, Driers (materials), Electric Heat Treatment, Electric Heating, Exergy, Heating Equipment, Humidity Control, Ozone Layer, Cost Benefit Analysis, Air space, Capital costs, Desiccant cooling, Desiccant cooling systems, Electric heater, EXCEM, Exergoeconomic, Exergy Analysis, Exergy loss, Expansion valves, Fresh air, Thermodynamic loss, Cooling systems, Driers (materials), Electric heat treatment, Electric heating, Exergy, Heating equipment, Humidity control, Ozone layer, Cost benefit analysis, Exergoeconomic, Desiccant Cooling, EXCEM, Exergy Analysis, Exergoeconomic, Desiccant Cooling, Exergy Analysis, EXCEM
Fields of Science
0211 other engineering and technologies, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
12
Source
Energy Conversion and Management
Volume
69
Issue
Start Page
9
End Page
16
PlumX Metrics
Citations
CrossRef : 10
Scopus : 12
Captures
Mendeley Readers : 55
SCOPUS™ Citations
12
checked on Apr 09, 2026
Web of Science™ Citations
12
checked on Apr 09, 2026
Google Scholar™


