Investigating the exergetic and environmental effects of subcooling and superheating processes on the performance of direct expansion systems
| dc.contributor.author | M. Ziya Sogut | |
| dc.contributor.author | Hikmet Tahir Karakoc | |
| dc.contributor.author | Zuhal Oktay | |
| dc.contributor.author | A. Hepbasli | |
| dc.contributor.author | Oktay, Zuhal | |
| dc.contributor.author | Hepbasli, Arif | |
| dc.contributor.author | Sogut, M. Ziya | |
| dc.contributor.author | Karakoç, Hikmet | |
| dc.date.accessioned | 2025-10-06T17:52:35Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | Recently subcooling and superheating applications which are proposed as an approach for the efficient use of energy have positive effect on the emission next to increasing the energy efficiency. This study examines energetic exergetic and environmental effects of subcooling and superheating processes in cooling applications separately. In this study a direct expansion system(DX) which is usedwidely in supermarket cooling applications is taken into consideration. The evaporator temperatures of −25 °C and 0 °C the refrigerants of R-22 R-404A and R-134a which are preferred widely in DX systems and minimum and maximum leakage rates of 3 and 30 % are taken as reference values for the analysis. According to the results while subcooling and subheating processes increase approximately 10 % of COP and exergy efficiencies based on refrigerants and decrease CO2 emissions for all refrigerants. The study also concluded with an emphasis on the importance of subcooling and superheating applications especially for DX systems and the importance of the preference refrigerant. © 2017 Elsevier B.V. All rights reserved. | |
| dc.identifier.doi | 10.1007/978-3-319-04681-5_68 | |
| dc.identifier.isbn | 9783319046808, 9783319046815 | |
| dc.identifier.isbn | 9783319046815 | |
| dc.identifier.isbn | 9783319046808 | |
| dc.identifier.scopus | 2-s2.0-84949604886 | |
| dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84949604886&doi=10.1007%2F978-3-319-04681-5_68&partnerID=40&md5=31baff1e2dc7d913e59edd2fd779341a | |
| dc.identifier.uri | https://gcris.yasar.edu.tr/handle/123456789/10011 | |
| dc.identifier.uri | https://doi.org/10.1007/978-3-319-04681-5_68 | |
| dc.language.iso | English | |
| dc.publisher | Springer International Publishing | |
| dc.relation.ispartof | Progress in Exergy, Energy, and the Environment | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Co2 Emission, Cop, Dx Systems, Exergy Analyses, Refrigerants, Carbon Dioxide, Energy Efficiency, Exergy, Refrigerants, Co2 Emissions, Cooling Applications, Direct Expansion Systems, Efficient Use Of Energy, Evaporator Temperature, Exergy Analysis, Exergy Efficiencies, Reference Values, Cooling | |
| dc.subject | Carbon dioxide, Energy efficiency, Exergy, Refrigerants, CO2 emissions, Cooling applications, Direct expansion systems, Efficient use of energy, Evaporator temperature, Exergy Analysis, Exergy efficiencies, Reference values, Cooling | |
| dc.subject | DX Systems | |
| dc.subject | Exergy Analyses | |
| dc.subject | Refrigerants | |
| dc.subject | COP | |
| dc.subject | CO2 Emission | |
| dc.title | Investigating the exergetic and environmental effects of subcooling and superheating processes on the performance of direct expansion systems | |
| dc.type | Book Part | |
| dspace.entity.type | Publication | |
| gdc.author.scopusid | 7801694496 | |
| gdc.author.scopusid | 26653753500 | |
| gdc.author.scopusid | 22979722100 | |
| gdc.author.scopusid | 55131010100 | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C5 | |
| gdc.coar.type | text::book::book part | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | ||
| gdc.description.departmenttemp | [Sogut M.Z.] Technical and Computer Applications Center, Military Academy, Ankara, Turkey; [Karakoç H.] Faculty of Aeronautics and Astronautics, Anadolu University, Eskisehir, Turkey; [Oktay Z.] Department of Energy Systems Engineering, Faculty of Engineering, Recep Tayyip Erdoğan University, Rize, Turkey; [Hepbasli A.] Department of Energy Systems Engineering, Faculty of Engineering, Yasar University, Bornova, 35100, Izmir, Turkey | |
| gdc.description.endpage | 722 | |
| gdc.description.publicationcategory | Kitap Bölümü - Uluslararası | |
| gdc.description.startpage | 713 | |
| gdc.identifier.openalex | W2474400522 | |
| gdc.index.type | Scopus | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 0.0 | |
| gdc.oaire.influence | 2.3811355E-9 | |
| gdc.oaire.isgreen | true | |
| gdc.oaire.keywords | Dx Systems | |
| gdc.oaire.keywords | Refrigerants | |
| gdc.oaire.keywords | Co2 Emission | |
| gdc.oaire.keywords | Cop | |
| gdc.oaire.keywords | Exergy Analyses | |
| gdc.oaire.popularity | 6.1148664E-10 | |
| gdc.oaire.publicfunded | false | |
| gdc.openalex.collaboration | National | |
| gdc.openalex.fwci | 1.7404 | |
| gdc.openalex.normalizedpercentile | 0.86 | |
| gdc.opencitations.count | 0 | |
| gdc.plumx.mendeley | 6 | |
| gdc.plumx.scopuscites | 2 | |
| gdc.scopus.citedcount | 2 | |
| gdc.virtual.author | Hepbaşli, Arif | |
| oaire.citation.endPage | 722 | |
| oaire.citation.startPage | 713 | |
| person.identifier.scopus-author-id | Sogut- M. Ziya (26653753500), Karakoc- Hikmet Tahir (22979722100), Oktay- Zuhal (7801694496), Hepbasli- A. (55131010100) | |
| relation.isAuthorOfPublication | 5ed55b5a-c6f7-47f9-9ff2-354ea25b338e | |
| relation.isAuthorOfPublication.latestForDiscovery | 5ed55b5a-c6f7-47f9-9ff2-354ea25b338e | |
| relation.isOrgUnitOfPublication | ac5ddece-c76d-476d-ab30-e4d3029dee37 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ac5ddece-c76d-476d-ab30-e4d3029dee37 |
