A robotic system to prepare IV solutions

dc.contributor.author Mehmet S. Unluturk
dc.contributor.author Ozgur Tamer
dc.contributor.author Semih Utku
dc.date NOV
dc.date.accessioned 2025-10-06T16:21:26Z
dc.date.issued 2018
dc.description.abstract Drugs need to be used regularly and correctly in order to be effective. When medicines are used correctly negativities that threaten human health and life can be avoided but they can cause unwanted situations that can occur until the end of life when they are used incorrectly. The most common drug administration errors in hospitals are: The wrong dosage of the drug given to the patient the timing and / or the method of administration the wrong drug given to the patient the drug given to the wrong patient or even not given. Furthermore the information about the drug that is administered to the patient may not be registered at all. In this research a robotic drug preparation system and a communication server accepting prescription orders have been developed. Component engineering methodology is further utilized in the design of the Drug Preparation System to maximize reuse increase product reliability reduce design code and test efforts. The IV Robotic Drug Preparation Robot is composed of a robotic work station and a Cartesian carrier to carry the work station to the desired location. The robotic work station has several grippers to handle syringes to pull the piston of the syringe and to lock the closed system connector to the vial. The IV Robotic Drug Preparation System and communication server are developed and being used in the hospitals. Due to this system medicines left unused in vials can be used and a great amount of savings is obtained from the drug purchases.
dc.identifier.doi 10.1016/j.ijmedinf.2018.09.011
dc.identifier.issn 1386-5056
dc.identifier.uri http://dx.doi.org/10.1016/j.ijmedinf.2018.09.011
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/6872
dc.language.iso English
dc.publisher ELSEVIER IRELAND LTD
dc.relation.ispartof International Journal of Medical Informatics
dc.source INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS
dc.subject Robotic drug preparation system, Closed system connectors, Hospital information systems, Oncology, HL7
dc.subject ADVERSE DRUG EVENTS, MEDICATION ERRORS, ANTICANCER DRUGS, INTENSIVE-CARE, CHEMOTHERAPY, QUALITY, SAFETY
dc.title A robotic system to prepare IV solutions
dc.type Article
dspace.entity.type Publication
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.endpage 69
gdc.description.startpage 61
gdc.description.volume 119
gdc.identifier.openalex W2891521504
gdc.identifier.pmid 30342687
gdc.index.type WoS
gdc.oaire.diamondjournal false
gdc.oaire.downloads 0
gdc.oaire.impulse 1.0
gdc.oaire.influence 2.569277E-9
gdc.oaire.isgreen true
gdc.oaire.keywords Quality Control
gdc.oaire.keywords Drug Compounding
gdc.oaire.keywords Humans
gdc.oaire.keywords Medication Errors
gdc.oaire.keywords Antineoplastic Agents
gdc.oaire.keywords Robotics
gdc.oaire.popularity 3.2328031E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 03 medical and health sciences
gdc.oaire.sciencefields 0302 clinical medicine
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.oaire.views 19
gdc.openalex.collaboration National
gdc.openalex.fwci 1.3557
gdc.openalex.normalizedpercentile 0.84
gdc.opencitations.count 3
gdc.plumx.mendeley 51
gdc.plumx.pubmedcites 1
gdc.plumx.scopuscites 6
oaire.citation.endPage 69
oaire.citation.startPage 61
person.identifier.orcid Tamer- Ozgur/0000-0002-5776-6627, UTKU- Semih/0000-0002-8786-560X
project.funder.name Scientific and Technical Research Council of Turkey (TUBITAK) [3150499]
publicationvolume.volumeNumber 119
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files