Development of an integrated underfloor heating system model in TRNSYS and performance assessments

Loading...
Publication Logo

Date

2024

Authors

Okan Gök
Nezir Yağız Çam
Ersin Alptekin
Mehmet Akif Ezan
Aytunç Erek

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Ltd

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

In this study a transient model for a solar underfloor heating system with a sensible heat thermal energy storage (SHTES) system to meet the heating demand of a residential building is developed in TRNSYS software. As a novelty in the current model rather than using the built-in modules in the software an in-house MATLAB routine is implemented in TRNSYS to simulate the spatial and temporal variations inside a 2D slab-type SHTES tank. Long-term dynamic simulations are conducted to discuss the influences of the design and working parameters on the (i) energetic and exergetic performances (ii) solar fraction and (iii) CO<inf>2</inf> emissions associated with the alternative underfloor heating systems. Parametric analyses are performed for climatically different locations such as Izmir (Csa: Hot-summer Mediterranean climate) and Erzurum (Dfb: Warm-summer humid continental climate). Variations in charging loop mass flow rates have minimal impact on the overall system performance in Izmir and Erzurum compared to other design and working parameters. The highest energy efficiencies of the solar-aided underfloor heating system for Izmir and Erzurum are achieved for a comfort temperature of 20 °C with 32.9 % and 24.6 % respectively. Regarding exergy efficiency the highest was determined as 4.04 % with a 23.5 °C comfort temperature in Izmir and 3.89 % with a comfort temperature of 20 °C in Erzurum. As a final result of the environmental assessments integrating solar SHTES especially with a natural gas-based auxiliary heater significantly reduces CO<inf>2</inf> emissions by 99.6 % and 50.0 % in Izmir and Erzurum respectively. © 2024 Elsevier B.V. All rights reserved.

Description

Keywords

Energetic Efficiency, Environmental Assessments, Exergetic Efficiency, Sensible Heat Thermal Energy Storage, Solar Energy, Trnsys, Underfloor Heating, Carbon Dioxide, Energy Efficiency, Environmental Impact, Gas Emissions, Heat Storage, Heating Equipment, Solar Energy, Thermal Energy, Comfort Temperatures, Design Parameters, Energetic Efficiency, Environmental Assessment, Erzurum, Exergetic Efficiency, Sensible Heat Thermal Energy Storages, Trnsys, Underfloor Heating, Underfloor Heating Systems, Matlab, Carbon dioxide, Energy efficiency, Environmental impact, Gas emissions, Heat storage, Heating equipment, Solar energy, Thermal energy, Comfort temperatures, Design parameters, Energetic efficiency, Environmental assessment, Erzurum, Exergetic efficiency, Sensible heat thermal energy storages, TRNSYS, Underfloor heating, Underfloor heating systems, MATLAB, TRNSYS, Solar Energy, Exergetic Efficiency, Sensible Heat Thermal Energy Storage, Underfloor Heating, Energetic Efficiency, Environmental Assessments

Fields of Science

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
4

Source

Journal of Energy Storage

Volume

84

Issue

Start Page

110993

End Page

PlumX Metrics
Citations

CrossRef : 4

Scopus : 4

Captures

Mendeley Readers : 15

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.5326

Sustainable Development Goals