Near-Fault Earthquake Ground Motion and Seismic Isolation Design

dc.contributor.author Mustafa O. Erdik
dc.contributor.author Bahadır Şadan
dc.contributor.author Cüneyt Tüzün
dc.contributor.author Mine Betul Demircioglu-Tumsa
dc.contributor.author Ömer Ülker
dc.contributor.author Ebru Harmandar
dc.contributor.author Erdik, Mustafa
dc.contributor.author Ülker, Ömer
dc.contributor.author Şadan, Bahadır
dc.contributor.author Harmandar, Ebru
dc.contributor.author Demircioglu-Tumsa, Mine B.
dc.contributor.author Tüzün, Cüneyt
dc.contributor.editor G.P. Cimellaro
dc.date.accessioned 2025-10-06T17:49:44Z
dc.date.issued 2023
dc.description.abstract Seismic isolation is one of the most reliable passive structural control techniques with adequately established standards for the earthquake protection of structures from earthquakes. However it has been shown that the seismic isolation systems may not function the best for the near-fault ground motions since in the proximity of a capable fault the ground motions are significantly affected by the rupture mechanism and may generate high demands on the isolation system and the structure. In fact several earthquake resistant design codes state that the seismically isolated structures located at near-fault sites should be designed by considering larger seismic demands than the demand on structures at far-field sites. When the fault ruptures in forward direction to the site most of the seismic energy arrives in coherent long-period ground velocity pulses. The ground-motion prediction equations (GMPEs) typically cannot account for such effects with limited distance metrics and lack adequate data at large magnitudes and near distances. For the reliable earthquake design of the isolated structure in near fault conditions that meets the performance objectives the 3D design basis ground motion(s) need to be appropriately assessed. Measures in the design of the isolation system such as modifications in the stiffness and damping characteristics as well as in the limitation of vertical effects are needed. The behavior of the base-isolated buildings under near-fault (NF) ground motions with fling-step and forward-directivity characteristics are investigated with a rational assessment of design-basis near-fault ground motion are investigated in a parametric format. The parametric study includes several variables including the structural system flexibility, number of stories, isolation system characteristic (yield) strength and the isolation periods related to the post-elastic stiffness. Furthermore the effect of additional damping by viscous dampers were tested for some selected cases. Important findings observed from the parametric performance results and the overall conclusions of the study are provided. © 2023 Elsevier B.V. All rights reserved.
dc.identifier.doi 10.1007/978-3-031-21187-4_9
dc.identifier.isbn 9789819620951, 9789819674879, 9789819616053, 9783031988929, 9783031927539, 9783031920431, 9789819652051, 9789819620333, 9789811613029, 9789819798308
dc.identifier.isbn 9783031211867
dc.identifier.isbn 9783031211874
dc.identifier.isbn 9783031211898
dc.identifier.issn 23662565, 23662557
dc.identifier.issn 2366-2557
dc.identifier.issn 2366-2565
dc.identifier.scopus 2-s2.0-85148693217
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-85148693217&doi=10.1007%2F978-3-031-21187-4_9&partnerID=40&md5=8cacc1c45626bb7dfdb7cd310994cbf1
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/8580
dc.identifier.uri https://doi.org/10.1007/978-3-031-21187-4_9
dc.language.iso English
dc.publisher Springer Science and Business Media Deutschland GmbH
dc.relation.ispartof 17th World Conference on Seismic Isolation WCSI 2022
dc.relation.ispartofseries Lecture Notes in Civil Engineering
dc.rights info:eu-repo/semantics/closedAccess
dc.source Lecture Notes in Civil Engineering
dc.subject Base-isolated Buildings, Fling-step, Forward-directivity, Near-fault Ground Motions, Pulse Period, Equations Of Motion, Faulting, Motion Estimation, Seismic Design, Stiffness, Structural Dynamics, Base-isolated Building, Fling-step, Forward Directivity, Isolated Structures, Isolation Systems, Near Fault Ground Motion, Near-fault, Pulse Period, Seismic Isolation, Damping
dc.subject Equations of motion, Faulting, Motion estimation, Seismic design, Stiffness, Structural dynamics, Base-isolated building, Fling-step, Forward directivity, Isolated structures, Isolation systems, Near fault ground motion, Near-fault, Pulse period, Seismic isolation, Damping
dc.subject Near-Fault Ground Motions
dc.subject Pulse Period
dc.subject Fling-step
dc.subject Forward-directivity
dc.subject Base-Isolated Buildings
dc.title Near-Fault Earthquake Ground Motion and Seismic Isolation Design
dc.type Conference Object
dspace.entity.type Publication
gdc.author.id Sadan, Bahadir/0000-0001-7572-2794
gdc.author.scopusid 58114249800
gdc.author.scopusid 57201256820
gdc.author.scopusid 7003962489
gdc.author.scopusid 35977149500
gdc.author.scopusid 57203959997
gdc.author.scopusid 36091176200
gdc.author.wosid Sadan, Bahadir/AAF-7601-2020
gdc.bip.impulseclass C4
gdc.bip.influenceclass C4
gdc.bip.popularityclass C4
gdc.coar.type text::conference output
gdc.collaboration.industrial false
gdc.description.department
gdc.description.departmenttemp [Erdik, Mustafa] Bogazici Univ, Dept Earthquake Engn, Istanbul, Turkiye; [Sadan, Bahadir] MEF Univ, Dept Civil Engn, Istanbul, Turkiye; [Tuzun, Cuneyt] Yasar Univ, Dept Civil Engn, Izmir, Turkiye; [Demircioglu-Tumsa, Mine B.; Ulker, Omer] Turkish Earthquake Fdn, Istanbul, Turkiye; [Harmandar, Ebru] Sitki Kocman Univ, Dept Civil Engn, Mugla, Turkiye
gdc.description.endpage 152
gdc.description.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
gdc.description.startpage 117
gdc.description.volume 309
gdc.description.woscitationindex Conference Proceedings Citation Index - Science
gdc.identifier.openalex W4313612995
gdc.identifier.wos WOS:000963575900009
gdc.index.type Scopus
gdc.index.type WoS
gdc.oaire.diamondjournal false
gdc.oaire.impulse 7.0
gdc.oaire.influence 3.0589133E-9
gdc.oaire.isgreen false
gdc.oaire.keywords Slip
gdc.oaire.keywords Inclusion
gdc.oaire.keywords Directivity
gdc.oaire.keywords Near-fault ground motions
gdc.oaire.keywords Pgv
gdc.oaire.keywords Pulse period
gdc.oaire.keywords Base-isolated buildings
gdc.oaire.keywords Pulses
gdc.oaire.keywords Fling-step
gdc.oaire.keywords Forward-directivity
gdc.oaire.keywords Components
gdc.oaire.keywords Displacement spectra
gdc.oaire.keywords Model
gdc.oaire.popularity 7.2198345E-9
gdc.oaire.publicfunded false
gdc.openalex.collaboration National
gdc.openalex.fwci 10.697
gdc.openalex.normalizedpercentile 0.99
gdc.openalex.toppercent TOP 10%
gdc.opencitations.count 3
gdc.plumx.mendeley 7
gdc.plumx.scopuscites 7
gdc.scopus.citedcount 9
gdc.virtual.author Tüzün, Cüneyt
gdc.wos.citedcount 6
oaire.citation.endPage 152
oaire.citation.startPage 117
person.identifier.scopus-author-id Erdik- Mustafa O. (7003962489), Şadan- Bahadır (58114249800), Tüzün- Cüneyt (35977149500), Demircioglu-Tumsa- Mine Betul (57201256820), Ülker- Ömer (57203959997), Harmandar- Ebru (36091176200)
publicationvolume.volumeNumber 309 LNCE
relation.isAuthorOfPublication 7fae5b65-4c00-4e60-a19b-ba79ab1c58ee
relation.isAuthorOfPublication.latestForDiscovery 7fae5b65-4c00-4e60-a19b-ba79ab1c58ee
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files