Abstract
The main objective of this study is to comprehensively perform exergy analysis of the tunnel furnace and the tunnel dryer which was selected as the control volume and involved in a brick production line. The analysis was based on the real data measured over a one-year period at a working brick factory with a daily production capacity of 392 tons of fired bricks. Energy and exergy efficiencies of the control volume were obtained to be 76.46% and 12.90% for dead state values of 25 degrees C and 1.013 atm respectively.
Description
ORCID
Keywords
brick factory, tunnel furnace, tunnel dryer, energy and exergy analysis, KILN, OPTIMIZATION, ENERGY, FUEL, Brick Factory, Energy and Exergy Analysis, Tunnel Dryer, Tunnel Furnace, Exergy Analysis, Energy, Optimization, Energy, brick factory, Kiln, Fuel, tunnel furnace, tunnel dryer, energy and exergy analysis
Fields of Science
0211 other engineering and technologies, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
N/A
Source
International Journal of Exergy
Volume
36
Issue
2-4
Start Page
208
End Page
226
PlumX Metrics
Citations
Scopus : 1
Captures
Mendeley Readers : 2
SCOPUS™ Citations
1
checked on Apr 09, 2026
Web of Science™ Citations
1
checked on Apr 09, 2026
Google Scholar™