Novel combined extended-advanced exergy analysis methodology as a new tool to assess thermodynamic systems
Loading...

Date
2021
Authors
Emin Açıkkalp
Hakan Caliskan
Onder Altuntas
A. Hepbasli
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Ltd
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
In this study a novel combined extended-advanced exergy analysis method is developed for assessing thermodynamic systems. The method is established by combining extended exergy analysis with advanced exergy analysis and the so-called extended-advanced exergy analysis. The methodology used in the novel analysis method is different from only extended exergy analysis and only advanced exergy analysis but the criteria are the same to reach the goal. This proposed method is applied to a gas turbine system as a case study to show its variability. The gas turbine system considered consists of a combustion chamber a compressor and turbine units. The conventional (Fuel-Product approach) advanced and extended exergy analyses are separately applied to the case study system for the comparison with the novel combined extended-advanced exergy analysis. It is seen that the combined extended-advanced exergy analysis results of the case study are not exactly the same with the advanced and extended exergy analyses’ results. The reason for this is its comprehensive joint of various thermodynamic analysis methodologies integrating all materials capital labor energy and environmental effect instead of the relation between components and their improvement potentials in one analysis. But it is assessed that the novel analysis tool is able to apply all of those analyses into one simple methodology. The exergy efficiencies of the case study are 28% and 31% by considering the conventional and extended exergy analyses respectively. This means that all input parameters including labor capital and environment are used with better efficiency. Also the exogenous exergy destruction rate (159 kW) is higher for the combined extended-advanced exergy analysis (384 kW). This shows that the relations between other components are increased for the turbine. Another important change is shown in avoidable exogenous exergy destruction rate for the turbine increasing from 374 kW to 833 kW. This new combined method is useful to those who wish to apply advanced and extended exergy analyses through a new practical assessment way. © 2021 Elsevier B.V. All rights reserved.
Description
Keywords
Advanced Exergy, Combined Extended-advanced Exergy, Efficiency, Extended Exergy, Gas Turbine, Mexogenous, Combustion Chambers, Gas Turbines, Thermoanalysis, Advanced Exergy, Analysis Method, Case-studies, Combined Extended-advanced Exergy, Exergy Analysis, Exergy Destructions, Extended Exergies, Mexogenous, Thermodynamic Systems, Turbine Systems, Exergy, Combustion chambers, Gas turbines, Thermoanalysis, Advanced exergy, Analysis method, Case-studies, Combined extended-advanced exergy, Exergy Analysis, Exergy destructions, Extended exergies, Mexogenous, Thermodynamic systems, Turbine systems, Exergy
Fields of Science
0211 other engineering and technologies, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
21
Source
Energy Conversion and Management
Volume
236
Issue
Start Page
114019
End Page
Collections
PlumX Metrics
Citations
CrossRef : 21
Scopus : 24
Captures
Mendeley Readers : 31
Google Scholar™


