An exergetic performance improvement potential of a modified ejector-enhanced auto-cascade refrigeration cycle
Loading...

Date
2025
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
INDERSCIENCE ENTERPRISES LTD
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
This study examines both conventional and advanced exergy analyses of a modified ejector-enhanced auto-cascade refrigeration (MEACR) cycle. Conventional exergy analysis shows that the proposed model significantly improves exergy efficiency compared to similar ejector-enhanced auto-cascade refrigeration cycles in the literature. Advanced exergy analysis reveals that 63.47% of the total exergy destruction is avoidable. When the components of the MEACR cycle are investigated 56.31% of the exergy destruction is attributed to the endogenous part. The low-temperature cycle (LTC) compressor has the highest avoidable endogenous exergy destruction rate of 12.64 kW with 38.5%.
Description
ORCID
Keywords
refrigeration, auto-cascade refrigeration, ejector, exergy analysis, advanced exergy analysis, Ejector, Auto-Cascade Refrigeration, Advanced Exergy Analysis, Refrigeration, Exergy Analysis, Advanced Exergy Analysis; Auto-cascade Refrigeration; Ejector; Exergy Analysis; Refrigeration; Ejectors (pumps); Advanced Exergy Analyze; Auto-cascade Refrigeration; Ejector; Exergetic Performance; Exergy Analysis; Exergy Destructions; Exergy Efficiencies; Low Temperature Cycles; Refrigeration Cycles; Chilling, refrigeration, auto-cascade refrigeration, advanced exergy analysis, ejector, exergy analysis
Fields of Science
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
N/A
Source
International Journal of Exergy
Volume
46
Issue
3-4
Start Page
228
End Page
243