A comparative study on conventional and advanced exergetic analyses of geothermal district heating systems based on actual operational data

dc.contributor.author Arif Hepbasli
dc.contributor.author Ali Kecebas
dc.date JUN
dc.date.accessioned 2025-10-06T16:21:17Z
dc.date.issued 2013
dc.description.abstract This paper comparatively evaluates exergy destructions of a geothermal district heating system (GDHS) using both conventional and advanced exergetic analysis methods to identify the potential for improvement and the interactions among the components. As a real case study the Afyon GDHS in Afyonkarahisar Turkey is considered based on actual operational data. For the first time advanced exergetic analysis is applied to the GDHSs in which the exergy destruction rate within each component is split into unavoidable/avoidable and endogenous/exogenous parts. The results indicate that the interconnections among all the components are not very strong. Thus one should focus on how to reduce the internal inefficiency (destruction) rates of the components. The highest priority for improvement in the advanced exergetic analysis is in the re-injection pump (PM-IX) while it is the heat exchanger (HEX-III) in the conventional analysis. In addition there is a substantial influence on the overall system as the total avoidable exergy destruction rate of the heat exchanger (HEX-V) has the highest value. On the overall system basis the value for the conventional exergetic efficiency is determined to be 29.29% while that for the modified exergetic efficiency is calculated to be 34.46% through improving the overall components. (c) 2013 Elsevier B.V. All rights reserved.
dc.identifier.doi 10.1016/j.enbuild.2013.02.019
dc.identifier.issn 0378-7788
dc.identifier.uri http://dx.doi.org/10.1016/j.enbuild.2013.02.019
dc.identifier.uri https://gcris.yasar.edu.tr/handle/123456789/6808
dc.language.iso English
dc.publisher ELSEVIER SCIENCE SA
dc.relation.ispartof Energy and Buildings
dc.source ENERGY AND BUILDINGS
dc.subject Geothermal energy, District heating system, Exergy destruction, Conventional exergetic analysis, Advanced exergetic analysis, Buildings
dc.subject CYCLE POWER-PLANT, TURKEY, PERFORMANCE, BALCOVA, COSTS, IZMIR
dc.title A comparative study on conventional and advanced exergetic analyses of geothermal district heating systems based on actual operational data
dc.type Article
dspace.entity.type Publication
gdc.bip.impulseclass C4
gdc.bip.influenceclass C4
gdc.bip.popularityclass C4
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.endpage 201
gdc.description.startpage 193
gdc.description.volume 61
gdc.identifier.openalex W2020320562
gdc.index.type WoS
gdc.oaire.diamondjournal false
gdc.oaire.impulse 16.0
gdc.oaire.influence 5.0230002E-9
gdc.oaire.isgreen true
gdc.oaire.popularity 1.1722601E-8
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0211 other engineering and technologies
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.collaboration National
gdc.openalex.fwci 8.2597
gdc.openalex.normalizedpercentile 0.98
gdc.openalex.toppercent TOP 10%
gdc.opencitations.count 34
gdc.plumx.crossrefcites 21
gdc.plumx.mendeley 46
gdc.plumx.scopuscites 40
oaire.citation.endPage 201
oaire.citation.startPage 193
project.funder.name Afyon Geothermal Inc.- Turkey
publicationvolume.volumeNumber 61
relation.isOrgUnitOfPublication ac5ddece-c76d-476d-ab30-e4d3029dee37
relation.isOrgUnitOfPublication.latestForDiscovery ac5ddece-c76d-476d-ab30-e4d3029dee37

Files