Image enhancement in positron emission tomography using expectation maximization
Loading...

Date
2006
Authors
halil erol
Etem KÖKLÜKAYA
Ahmet Alkan
Journal Title
Journal ISSN
Volume Title
Publisher
Open Access Color
OpenAIRE Downloads
OpenAIRE Views
Abstract
Positron Emission Tomography (PET) tomography is one of the imaging modality. PET Tomography scanners collect measurements of a patient's in vivo radiotracer distribution. These measurements are reconstructed into cross-sectional images. Tomographic image reconstruction forms images of functional information in nuclear medicine applications and the same principles can be applied to modalities such as X-ray computed tomography and Single Photon Computed Tomography(SPECT). Reconstruction in PET can be done in two ways direct and algebraic methods. Iterative reconstruction is an algebraic reconstruction method. The great advantage of iterative methods is that correction to attenuation and depth-dependent detector response can be incorporated to the reconstruction process. One of the drawbacks of the iterative reconstruction methods is the huge computation due to large system matrices. This system matrix is very sparse. In Matlab 7 matrices having elements more than 100 million can not be executed or stored due to its size restriction. To overcome this problem we have implemented a new storage technique. By this technique large system matrices can be manipulated in Matlab7. Reconstructed images are compared with the images which are obtained by using direct reconstruction algorithms namely Filtered Backprojection.
Description
Keywords
Görüntüleme Bilimi ve Fotoğraf Teknolojisi-Radyoloji- Nükleer Tıp- Tıbbi Görüntüleme
Fields of Science
Citation
1. Siddon RL. Fast calculation of the exact radiological path for a threedimensional CT array. Med Phys. 1985,12:252-255.2. Lange K Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr. 1984,8:306-316.3. Kaufman L. Implementing and accelerating the EM algorithm for positron emission tomography. IEEE Trans Med Imaging. 1987,MI-6:37-51.4. Shepp LA Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging. 1982,MI-1:113-122.5. Llacer J Veklerov E Coakley K Hoffman E Nunez J. Statistical analysis of maximum likelihood estimator images of human brain FDG PET studies. IEEE Trans Med Imaging. 1993,12:215-2316. J. Nuyts \"On estimating the variance of postsmoothed MLEM images\" IEEE Trans. Nucl. Sci. vol. 49 pp. 714-721 June 2002.
