Avoidable and unavoidable exergy destructions of a fluidized bed coal combustor and a heat recovery steam generator
Loading...

Date
2015
Authors
Meliha Callak
Firuz Balkan
Arif Hepbasli
Journal Title
Journal ISSN
Volume Title
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Open Access Color
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Advanced exergy analysis was performed using the actual operational data taken from a fluidized bed coal combustor (FBCC) and a heat recovery steam generator (HRSG) in a textile plant located at Torbali Izmir. First the conventional exergy analysis of the units was carried out. The exergetic efficiencies of the units were found to be 44.2% and 46.2% respectively. Advanced exergy analysis was then performed by splitting the exergy destructions of the units into avoidable and unavoidable parts. The avoidable exergy destruction rates of the FBCC and the HRSG were determined to be 2999 kW and 760 kW according to the measurements. Correspondingly the exergy efficiencies were modified to 53.1% and 48.1% respectively. (C) 2015 Elsevier Ltd. All rights reserved.
Description
Keywords
Energy analysis, Exergy analysis, Advanced exergy analysis, Fluidized bed, Textile plant, SYSTEM, GAS, Fluidized bed, Exergy analysis, Advanced exergy analysis, Textile plant, Energy analysis
Fields of Science
0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
28
Source
Energy Conversion and Management
Volume
98
Issue
Start Page
54
End Page
58